Expand | ||||||
---|---|---|---|---|---|---|
| ||||||
|
...
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
See RediGate 100 Hardware Manual#Certifications262157 for a list of certifications of the RediGate products. To ensure compliance with Electromagnetic Emissions Interference (EMI) standards, the user must install a ferrite on the Ethernet cable (see 262157).
...
Model | RediGate |
Width | 4.88” (12.40 cm) |
Length | 2.90“ (7.85 37 cm) (excluding connectors) |
Height | 1.35” (3.43 cm) (excluding DIN rail mount feet) |
Weight | 0.5 lbs (0.23 kg) |
...
Feature | Certification | Test Method and Limits |
---|---|---|
Radiated Emissions | US CFR Title 47, FCC Part 15B EN 61000-6-4:2007/A1:2011 | FCC Part 15.109, Class A ICES-003 Issue 7, Section 6.2 ANSI C63.4:2014, Section 8 EN 61000-6-4:2005/AC:2005 EN 55011:2009/A1:2010 EN 55032:2012/AC:2013 EN ETSI 301 489-1 V2.1.1 AS/NZS 32 VCCI 32 KDB 996369 (Module Integration Verification) |
Conducted Emissions | US CFR Title 47, FCC Part 15B EN 61000-6-4:2007/A1:2011 | FCC Part 15.107, Class A ICES-003 Issue 7, Section 6.1 ANSI C63.4:2014, Section 7 EN 61000-6-4:2005/AC:2005 EN 55011:2009/A1:2010 EN 55032:2012/AC:2013 EN ETSI 301 489-1 V2.1.1 AS/NZS 32 VCCI 32 |
Immunity | EN 61326-1:2013 | Electrostatic Discharge: IEC 61000-4-2:2008; 4 kV/8 kV Contact/Air Radiated Immunity: EFT-I/O lines: IEC 61000-4-4:2004/A1:2010; ±1 kV Surge-DC: IEC 61000-4-5:2014; ±0.5 kV Conducted Immunity – I/O lines: IEC 61000-4-6:2014; 3 Vrms |
Safety | UL 60950-1:2007 Conforms to IEC/EN 62368-1 | |
Environmental | RoHS (EU Directive 2011/65/EC) WEEE (EU Directive 2012/19/EU) | |
Hazardous Location | Class 1, Division 2, Groups A, B, C, and D, temp. T4 Conforms to ISA STD 12.12.01 |
...