RediGate Title Page Boilerplate

...

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

See Additionally, the RediGate models RG-110E-00-00 and RG-120E-00-00 have been to demonstrate compliance with Class A equipment requirements of CFR 47 15B, ICES-003 (Industry Canada), and CISPR 32:2015 (AS/NZS), and IEC 61000-6-4:2018. To ensure compliance with Electromagnetic Emissions RediGate 100 Hardware Manual#Certifications for a list of certifications of the RediGate products. To ensure compliance with Electromagnetic Emissions Interference (EMI) standards, the user must install a ferrite on the Ethernet cable (see 262157).

...

  • RG-1x0C-10-00: Telit EVDO cellular module (FCC ID: RI7DE910-DUAL. IC ID: 5131A-DE910DUAL)
  • RG-1x0C-21-00 or RG-1x0C-22-00: Telit GSM cellular module (FCC ID: RI7HE910. IC ID: 5131A-HE910)
  • RG-1x0C-30-00: U-blox uBlox CAT-M1 modem (FCC ID: XPY2AGQN4NNN. IC ID: 8595A-2AGQN4NNN)
  • RG-1x0C-40-00: Quectel CAT-M1 modem (FCC ID: XMR201707BG96. IC ID: 10224A-201709BG96)

Changes or modifications to the product not expressly approved by (Note that some early models of RG-110C-40-00 were built with the uBlox CAT-M1 modem and should be configured accordingly. Serial numbers include: 63263-xxxx, 63833-0001, 63908-0001, 64894-xxxx.)

Changes or modifications to the product not expressly approved by Elecsys Corporation could void the user’s authority to operate the equipment.

...

Connect power to the RediGate using a two-position Phoenix Contact plug (Phoenix part# 1827703 or compatible).  The orientation of positive and neutral wires as viewed from the front side of the RediGate is illustrated using the following symbol located on the product overlay:

Feature

Description

Operational Voltage

+9.5 to +28 V , 1.5 A max.

Overvoltage Protection

+50 V  maximum

Reverse Voltage Protection

-28 V  maximum

Operating Current @24V

110 mA  nominal

Power Consumption: *
RediGate 110E, 120E:
RediGate 110C, 120C:
*power excludes USB (normally unused)

Nominal Max 
2.5W     3W 
3W        5W

Environmental Characteristics

...

The EUT was tested for compliance to Directive 2014/30/EU of the European Parliament relating to electromagnetic compatibility using the following harmonized standards.

Feature

Certification

Test Method and Limits

Radiated Emissions

US CFR Title 47, FCC Part 15B
Canada’s ICES-003, Issue 6

EN 61000-6-4:2007/A1:2011
EN 55011:2009/A1:2010
CISPR 11
RCM

FCC Part 15.109, Class A
ICES-003 Issue 7, Section 6.2
ANSI C63.4:2014, Section 8
EN 61000-6-4:2005/AC:2005
EN 55011:2009/A1:2010
EN 55032:2012/AC:2013
EN ETSI 301 489-1 V2.1.1
AS/NZS 32
VCCI 32
KDB 996369 (Module Integration Verification)

Conducted Emissions

US CFR Title 47, FCC Part 15B
Canada’s ICES-003, Issue 6

EN 61000-6-4:2007/A1:2011
EN 55011:2009/A1:2010
CISPR 11
RCM

FCC Part 15.107, Class A
ICES-003 Issue 7, Section 6.1
ANSI C63.4:2014, Section 7
EN 61000-6-4:2005/AC:2005
EN 55011:2009/A1:2010
EN 55032:2012/AC:2013
EN ETSI 301 489-1 V2.1.1
AS/NZS 32
VCCI 32

Immunity

EN 61326-1:2013
EN ETSI 301 489-1 V2.1.1

Electrostatic Discharge: IEC 61000-4-2:2008; 4 kV/8 kV Contact/Air

Radiated Immunity:
IEC 61000-4-3:2006/A1:2007/A2:2010
3V/m, 80MHz – 1GHZ
3V/m, 1.4 – 2GHz;
3 V/m, 2-3GHz
3 V/m, 3-6GHz
80% amplitude modulation at 1kHz

EFT-I/O lines: IEC 61000-4-4:2004/A1:2010; ±1 kV

Surge-DC: IEC 61000-4-5:2014; ±0.5 kV

EFT-

Conducted Immunity – I/O lines: IEC 61000-4-

4:2004/A1:2010; ±1 kVConducted Immunity – I/O lines: IEC 61000-4-6:2014; 3 Vrms

6:2014; 3 Vrms

Safety

UL 60950-1:2007
CAN/CSA C22.2#60950-1:2007
IEC 60950-1

Conforms to IEC/EN 62368-1


Environmental

RoHS

WEEE (EU Directive 2012/19/EU)


Hazardous Location

Class 1, Division 2, Groups A, B, C, and D, temp. T4

Conforms to ISA STD 12.12.01

Certified to CSA STD C22.22 #213



RediGate 100 Hardware

The RediGate is supplied with a rugged metal housing, with hardware options that vary depending on the model and are indicated by symbols located on the product overlay. The front panel of the RediGate contains (in order from left to right):

...

The CAT-M1 modem is based on the u-blox SARA-R404 or Quectel BG96 or uBlox SARA-R410 wireless module and provides LTE/CAT-M1 wireless support. The SARA-R404 modem is certified for use on the Verizon cellular network. The SARA-R410 BG96 modem is certified for use on the Verizon and AT&T networks.The EVDO modem is based on the Telit DE910-DUAL wireless module and provides dual band 1xRTT/CDMA/EVDO wireless support.  The cellular network in the United States and other international networks. The SARA-R410 modem is certified for use on the Verizon cellular network.

The GSM/HSPA modem is based on the Telit HE910 wireless module and provides multi-band GSM/GPRS/EDGE/UMTS/HSPA+ wireless support.  The modem is certified for use on the AT&T cellular network in the United States, and the Telus cellular network in Canada.

The EVDO modem is based on the Telit DE910-DUAL wireless module and provides dual band 1xRTT/CDMA/EVDO wireless support.  The modem is certified for use on the Verizon cellular network.

The choice of modem may depend on the quality or availability of cellular service at the intended location for device installation.

...

The cellular connector requires an antenna with a standard male SMA plug and 50 ohm cable, with a minimum cable length of 20 cm. FCC requirements in the United States require a maximum gain (including cable loss) as follows:

Frequency

EVDO

GSM

CAT-M1
SARA-R410

CAT-M1
BG96

 746-787 MHz

(700 MHz band)

 n/an/a 3.67 dBi4.0 dBi

824-846 MHz

(850 MHz band)

5.12 dBi

5.22 dBi

4.10 dBi4.0 dBi

1712-1752 MHz

(1700 MHz band)

n/a

3.31 dBi

6.74 dBi

1851-1907 MHz

(1900 MHz band)

6.12 dBi

6.45 dBi

7.12 dBi4.0 dBi


Installing SIM Card

Include Page
RediGate 100 SIM Card Installation
RediGate 100 SIM Card Installation

...