Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.




 

Expand
titleElecsys Product and Support Information

Include Page
RediGate Title Page Boilerplate
RediGate Title Page Boilerplate

...

Feature

Certification

Test Method and Limits

Radiated Emissions

US CFR Title 47, FCC Part 15B
Canada’s ICES-003, Issue 6

EN 61000-6-4:2007/A1:2011
EN 55011:2009/A1:2010

FCC Part 15.109, Class A
ICES-003 Issue 7, Section 6.2
ANSI C63.4:2014, Section 8
EN 61000-6-4:2005/AC:2005
EN 55011:2009/A1:2010
EN 55032:2012/AC:2013
EN ETSI 301 489-1 V2.1.1
AS/NZS 32
VCCI 32
KDB 996369 (Module Integration Verification)

Conducted Emissions

US CFR Title 47, FCC Part 15B
Canada’s ICES-003, Issue 6

EN 61000-6-4:2007/A1:2011
EN 55011:2009/A1:2010

FCC Part 15.107, Class A
ICES-003 Issue 7, Section 6.1
ANSI C63.4:2014, Section 7
EN 61000-6-4:2005/AC:2005
EN 55011:2009/A1:2010
EN 55032:2012/AC:2013
EN ETSI 301 489-1 V2.1.1
AS/NZS 32
VCCI 32

Immunity

EN 61326-1:2013
EN ETSI 301 489-1 V2.1.1

Electrostatic Discharge: IEC 61000-4-2:2008; 4 kV/8 kV Contact/Air

Radiated Immunity:
IEC 61000-4-3:2006/A1:2007/A2:2010
3V/m, 80MHz – 1GHZ
3V/m, 1.4 – 2GHz;
3 V/m, 2-3GHz
3 V/m, 3-6GHz
80% amplitude modulation at 1kHz

EFT-I/O lines: IEC 61000-4-4:2004/A1:2010; ±1 kV

Surge-DC: IEC 61000-4-5:2014; ±0.5 kV

Conducted Immunity – I/O lines: IEC 61000-4-6:2014; 3 Vrms

Safety

UL 60950-1:2007
CAN/CSA C22.2#60950-1:2007IEC 60950-1

Conforms to IEC/EN 62368-1


Environmental

RoHS (EU Directive 20022011/9565/EC)

WEEE (EU Directive 2012/19/EU)


Hazardous Location

Class 1, Division 2, Groups A, B, C, and D, temp. T4

Conforms to ISA STD 12.12.01
Certified to CSA STD C22.22 #213


...