Expand | ||||||
---|---|---|---|---|---|---|
| ||||||
|
...
Feature | Certification | Test Method and Limits |
---|---|---|
Radiated Emissions | US CFR Title 47, FCC Part 15B EN 61000-6-4:2007/A1:2011 | FCC Part 15.109, Class A ICES-003 Issue 7, Section 6.2 ANSI C63.4:2014, Section 8 EN 61000-6-4:2005/AC:2005 EN 55011:2009/A1:2010 EN 55032:2012/AC:2013 EN ETSI 301 489-1 V2.1.1 AS/NZS 32 VCCI 32 KDB 996369 (Module Integration Verification) |
Conducted Emissions | US CFR Title 47, FCC Part 15B EN 61000-6-4:2007/A1:2011 | FCC Part 15.107, Class A ICES-003 Issue 7, Section 6.1 ANSI C63.4:2014, Section 7 EN 61000-6-4:2005/AC:2005 EN 55011:2009/A1:2010 EN 55032:2012/AC:2013 EN ETSI 301 489-1 V2.1.1 AS/NZS 32 VCCI 32 |
Immunity | EN 61326-1:2013 | Electrostatic Discharge: IEC 61000-4-2:2008; 4 kV/8 kV Contact/Air Radiated Immunity: EFT-I/O lines: IEC 61000-4-4:2004/A1:2010; ±1 kV Surge-DC: IEC 61000-4-5:2014; ±0.5 kV Conducted Immunity – I/O lines: IEC 61000-4-6:2014; 3 Vrms |
Safety | UL 60950-1:2007 Conforms to IEC/EN 62368-1 | |
Environmental | RoHS (EU Directive 2011/65/EC) WEEE (EU Directive 2012/19/EU) | |
Hazardous Location | Class 1, Division 2, Groups A, B, C, and D, temp. T4 Conforms to ISA STD 12.12.01 |
...